Then these are the maps with their axes and conversion factors that I have found some are not able to identify and map the fumes are not safe to be this:
08ABFA injection time 24x16 Axis X:Bar Y:IQ Z:us
09040E map pedal 8x16 X-Axis:RPM, Y:%pedal Z:Torque Nm
09053E map pedal 8x16 X-Axis:RPM, Y:%pedal Z:Torque Nm
090672 Limiter torque at operating temp the water 10x16 X-Axis:RPM, Y:Temp°C Z:Nm
084B48 Lim. pair, 8x1 X-Axis:RPM Z:Nm a 16-bit
08e684 Lim. pair, 8x1 X-Axis:RPM Z:Nm a 16-bit
08E664 Lim. pair, 8x1 X-Axis:RPM Z:Nm a 16-bit
0910E0 Lim. Pair 12X1 Axes XRPM Z:Nm a 16-bit
0912B8 Lim. Pair 12X1 Axes XRPM Z:Nm a 16-bit
091CC2 Lim. pair ??????
08F218 Lim. press???? 16x16 X-Axis:RPM, Y:IQ Z:??? 8bit
08F4D8 ??????? 16x16 8bit
08999E lim press map 16x16 16bit ?????
091B3A ???? 16x16 X-Axis:rpm, Y:IQ Z:??? 8bit
092976 ????? 16x16 X-Axis:RPM, Y:IQ Z:??? 8bit
092C24 ???? 16x16 X-Axis:RPM, Y:IQ Z:??? 8bit
092D64 ??? 16x16 X-Axis:RPM, Y:IQ Z:??? 8bit
091CFE ??? 10x10 8bit
0920D2 lim press turbo 16x16 X-Axis:RPM, Y:IQ Z:??? 8bit
092212 lim press turbo 16x16 X-Axis:RPM, Y:IQ Z:??? 8bit
0805FC should be the limiter flue 8x16
0806FC connected to the limiter fumes I think 8x16
090c36____________T. Over Boost__________16x16
090D76____________T. Over Boost__________16x16
CONVERSION FACTORS
BAR: 2,000 Offsett in the map -100
QI: 0,002930 OR 0,002941
US: Without conversion
RPM: Without conversion
%PEDAL ACC: 0,004
Nm: 0.023438
TEMP. WATER: 0,5